Blumenthal EZ, Girkin CA, Dotan S.

Neuro-Ophthalmology. 2006;30:111-115.
Department of Ophthalmology, Hebrew University-Hadassah Medical Center, Jerusalem, Israel. eblumenthal@md.huji.ac.il

ABSTRACT:

PURPOSE: To demonstrate that slow-growing intracranial suprasellar mass lesions can be associated with optic disc cupping, clinically indistinguishable from glaucomatous optic neuropathy.

CASES: At a neuro-ophthalmology tertiary clinic, a retrospective chart review identified four patients of presumed
normal tension glaucoma and supra-sellar tumors. In all four patients with normal intraocular pressure, the appearance of the optic disc resembled typical glaucomatous optic nerve damage with disc cupping and parapapillary atrophy.

CONCLUSION: In few patients, typical glaucomatous abnormalities of the optic nerve head may occur in association with slow-growing suprasellar tumors.

המאמר המלא- כקובץ PDF

Figures from this article:

 

גלאוקומה וקטרקט:
www.glaucoma.org.il

ניתוח

אבחנה

אתר זה נכתב ע”י פרופ’ איתן בלומנטל. באתר תמצאו אינפורמציה מעמיקה על האבחון והטיפול בגלאוקומה ובקטרקט. האינפורמציה באתר איננה תחליף לייעוץ רפואי.

פוסט קשור

PDF icon 1
Risk Factors and Incidence of Ocular Hypertension After Penetrating Keratoplasty
Faik Oruc¸oglu, MD, Eytan Z. Blumenthal, MD, Joseph Frucht-Pery, MD, and Abraham Solomon, MD Journal of Glaucoma. 2013 Feb 19. Kudret Eye Hospital, Istanbul, Turkey Department of Ophthalmology, Hadassah-Hebrew...
PDF filing cabinet
רשימת פרסומים מדעיים של פרופ' איתן בלומנטל
ORIGINAL RESEARCH PAPERS Blumenthal EZ. Adjusting the slit-lamp oculars: An unnecessary burden or a must?  Survey of Ophthalmology 1995;40(3):225-228. Abstract Full-text (PDF) Blumenthal EZ, Serpetopoulos...
PDF icon 1
Adjusting The Slit-Lamp Oculars: An Unnecessary Burden Or A Must?
Blumenthal EZ. Surv Ophthalmol. 1995 Nov-Dec;40(3):225-8. Department of Opthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjusting the slit-lamp eyepiece rings is perceived by some...
PDF icon 1
On Focusing The Slit-Lamp: Part I. An Inaccurate Ocular Setting–What Is There To Lose?
Blumenthal EZ, Serpetopoulos CN. Surv Ophthalmol. 1998 Jan-Feb;42(4):351-4. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT: Adjustments of the diopter rings on the...
PDF icon 1
On Focusing The Slit-Lamp: Part II. “The Fading-Slit Test” Verifying The Ocular Setting
Blumenthal EZ, Serpetopoulos CN Surv Ophthalmol. 1998 Jan-Feb;42(4):355-7. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT The focusing-rod test is considered the...