גלאוקומה וקטרקט, פרופ' איתן בלומנטל

פרופ' בלומנטל

gh

Quantifying Retinal Nerve Fiber Layer Thickness Histologically: A Novel Approach To Sectioning Of The Retina

Blumenthal EZ. Invest Ophthalmol Vis Sci. 2004 May;45(5):1404-9. Department of Ophthalmology, Hebrew University, Hadassah Medical Center, Jerusalem, Israel. eblumenthal@md.huji.ac.il ABSTRACT: PURPOSE: To present a technique of ocular sectioning that enables continuous histologic measurements of peripapillary retinal nerve fiber layer (RNFL) thickness in a concentric ring around the optic disc, corresponding to similar regions measured by …

Quantifying Retinal Nerve Fiber Layer Thickness Histologically: A Novel Approach To Sectioning Of The Retina לקריאה »

The Reliability Of Frequency-Doubling Perimetry In Young Children

Blumenthal EZ, Haddad A, Horani A, Anteby I. Ophthalmology. 2004 Mar;111(3):435-9. Comment in: Ophthalmology. 2005 Jan;112(1):169; author reply 169-70. Department of Ophthalmology, Hadassah University Hospital, PO Box 12000, Jerusalem 91120, Israel. eblumenthal@md.huji.ac.il ABSTRACT: OBJECTIVE: To evaluate whether healthy young children are able to perform automated static perimetry reliably using the frequency-doubling technology (FDT) perimeter. DESIGN: …

The Reliability Of Frequency-Doubling Perimetry In Young Children לקריאה »

Post-Brachytherapy Initial Tumour Regression Rate Correlates With Metastatic Spread In Posterior Uveal Melanoma

Kaiserman I, Anteby I, Chowers I, Blumenthal EZ, Kliers I, Pe’er J. Br J Ophthalmol. 2004 Jul;88(7):892-5. Department of Ophthalmology, Hadassah University Hospital, POB 12000, IL-91120 Jerusalem, Israel. Igork@cc.huji.ac.il ABSTRACT: AIM: To confirm the prognostic value of post-brachytherapy initial tumour regression rate in posterior uveal melanoma. METHODS: A prospective, comparative, observational cohort study was carried …

Post-Brachytherapy Initial Tumour Regression Rate Correlates With Metastatic Spread In Posterior Uveal Melanoma לקריאה »

Trabeculectomy and Phaco-Trabeculectomy with and without Peripheral Iridectomy

Kaplan-Messas A, Cohen Y, Blumenthal E, Avni I. Eur J Ophthalmol. 2009 Mar-Apr;19(2):231-4. Department of Ophthalmology, Assaf Harofeh Medical Center, Zerifin, affiliated with the Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv – Israel. audreykap@gmail.com ABSTRACT: PURPOSE: To compare the 1-year outcome of trabeculectomy and combined phaco-trabeculectomy that were performed with or without a …

Trabeculectomy and Phaco-Trabeculectomy with and without Peripheral Iridectomy לקריאה »

Using Unsupervised Learning With Variational Bayesian Mixture Of Factor Analysis To Identify Patterns Of Glaucomatous Visual Field Defects

Sample PA, Chan K, Boden C, Lee TW, Blumenthal EZ, Weinreb RN, Bernd A, Pascual J, Hao J, Sejnowski T, Goldbaum MH. Invest Ophthalmol Vis Sci. 2004 Aug;45(8):2596-605. Hamilton Glaucoma Center, Department of Ophthalmology, University of California-San Diego, La Jolla, 92093-0946, USA. psample@eyecenter.ucsd.edu ABSTRACT: PURPOSE: To determine whether an unsupervised machine learning classifier can identify …

Using Unsupervised Learning With Variational Bayesian Mixture Of Factor Analysis To Identify Patterns Of Glaucomatous Visual Field Defects לקריאה »

Patterns Of Glaucomatous Visual Field Progression Identified By Three Progression Criteria

Boden C, Blumenthal EZ, Pascual J, McEwan G, Weinreb RN, Medeiros F, Sample PA. Am J Ophthalmol. 2004 Dec;138(6):1029-36. Hamilton Glaucoma Center and Visual Function Laboratory, Department of Ophthalmology, University of California, San Diego, La Jolla, California 92093, USA. cboden@eyecenter.ucsd.edu ABSTRACT: PURPOSE: To determine typical patterns of repeatable glaucomatous visual field progression. DESIGN: Retrospective analysis …

Patterns Of Glaucomatous Visual Field Progression Identified By Three Progression Criteria לקריאה »

Operator Learning Effect And Interoperator Reproducibility Of The Scanning Laser Polarimeter With Variable Corneal Compensation

Frenkel S, Slonim E, Horani A, Molcho M, Barzel I, Blumenthal EZ. Ophthalmology. 2005 Feb;112(2):257-61. Department of Ophthalmology, Hebrew University-Hadassah Medical Center, Jerusalem, Israel. ABSTRACT: PURPOSE: To ascertain operator learning effect, and to quantify the interoperator reproducibility, using the newly introduced GDx VCC (variable corneal compensator) scanning laser polarimeter. DESIGN: Prospective instrument validation study. PARTICIPANTS: …

Operator Learning Effect And Interoperator Reproducibility Of The Scanning Laser Polarimeter With Variable Corneal Compensation לקריאה »

Inter-Device Reproducibility Of The Scanning Laser Polarimeter With Variable Cornea Compensation

Blumenthal EZ, Frenkel S. Eye. 2005 Mar;19(3):308-11. Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. eblumenthal@md.huji.ac.il ABSTRACT: OBJECTIVE: To evaluate the interdevice reproducibility of retinal nerve fibre layer (RNFL) thickness measurements obtained with the commercially available GDx-VCC, a scanning laser polarimeter with variable (individualized) corneal compensation. METHODS: A prospective instrument validation study in which 13 …

Inter-Device Reproducibility Of The Scanning Laser Polarimeter With Variable Cornea Compensation לקריאה »

The Effect Of Pupil Dilation On Scanning Laser Polarimetry With Variable Corneal Compensation

Horani A, Frenkel S, Blumenthal EZ. Ophthalmic Surg Lasers. 2006 May/June 37 (3). Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel. ABSTRACT BACKGROUND AND OBJECTIVE: The feasibility and reproducibility of scanning laser polarimetry performed through dilated pupils rather than through non-dilated pupils was tested. PATIENTS AND METHODS: One eye each of 36 subjects (12 normal, …

The Effect Of Pupil Dilation On Scanning Laser Polarimetry With Variable Corneal Compensation לקריאה »

Histological Measurement Of Retinal Nerve Fibre Layer Thickness

Frenkel S, Morgan JE, Blumenthal EZ. Eye 2005 May;19(5):491-8. Department of Ophthalmology, Hebrew University-Hadassah Medical Center, Jerusalem, Israel. ABSTRACT: PURPOSE: Accurate assessment of the retinal nerve fibre layer (RNFL) is central to the diagnosis and follow-up of glaucoma. The in vivo measurement of RNFL thickness by a variety of digital imaging technologies is becoming an …

Histological Measurement Of Retinal Nerve Fibre Layer Thickness לקריאה »