Measurement Of Choroidal Melanoma Basal Diameter By Wide-Angle Digital Fundus Camera: A Comparison With Ultrasound Measurement

Pe’er J, Sancho C, Cantu J, Eilam S, Barzel I, Shulman M, Blumenthal EZ. Ophthalmologica. 2006;220(3):194-7. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. peer@md.huji.ac.il ABSTRACT: PURPOSE: To compare the measurement of the basal diameter of choroidal melanoma, an important parameter for planning treatment and as a prognostic factor, by standardized ophthalmic ultrasound versus …

Measurement Of Choroidal Melanoma Basal Diameter By Wide-Angle Digital Fundus Camera: A Comparison With Ultrasound Measurement לקריאה »

Punch Biopsy Of Iris Lesions: A Novel Technique For Obtaining Histology Samples

Pe’er J, Blumenthal EZ, Frenkel S. Br J Ophthalmol. 2007 May;91(5):660-2. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, PO Box 12000, 91120 Jerusalem, Israel. peer@md.huji.ac.il ABSTRACT: AIM: To obtain iris biopsy samples of sufficient quality and quantity for histopathological analysis using a novel punch biopsy technique. METHODS: Two patients underwent iris tumour biopsy at an …

Punch Biopsy Of Iris Lesions: A Novel Technique For Obtaining Histology Samples לקריאה »

Early Transient Visual Acuity Loss After Lasik Due To Steroid-Induced Elevation Of Intraocular Pressure

Frucht-Pery J, Landau D, Raiskup F, Orucov F, Strassman E, Blumenthal EZ, Solomon A. J Refract Surg. 2007 Mar;23(3):244-51. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. ABSTRACT: PURPOSE: To report the clinical course of early transient reduction of uncorrected visual acuity (UCVA) after LASIK surgery resulting from steroid-induced elevation of intraocular pressure (IOP). …

Early Transient Visual Acuity Loss After Lasik Due To Steroid-Induced Elevation Of Intraocular Pressure לקריאה »

Morphometric Analysis Of Human Peripapillary Retinal Nerve Fiber Layer Thickness

Cohen MJ, Kaliner E, Frenkel S, Kogan M, Miron H, Blumenthal EZ. Invest Ophthalmol Vis Sci. 2008 Mar;49(3):941-4. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. ABSTRACT: PURPOSE: The peripapillary retinal nerve fiber layer (RNFL) thickness pattern in the normal human eye has been well characterized using data obtained with scanning laser polarimetry and …

Morphometric Analysis Of Human Peripapillary Retinal Nerve Fiber Layer Thickness לקריאה »

Measuring Choroidal Melanoma Basal Diameter: Using Ultrasound Vs. A New Wide–angle Fundus Camera

J.J. Pe’er, C. Sancho, J. Cantu, S. Eilam, I. Barzel, M. Shulman and E.Z. Blumenthal Invest Ophthalmol Vis Sci 2004;45: E-Abstract 1223. © 2004 ARVO 1223 – B34 Department of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel Commercial Relationships: J.J. Pe’er, None; C. Sancho, None; J. Cantu, None; S. Eilam, None; I. Barzel, None; M. Shulman, None; E.Z. Blumenthal, None. Grant Identification: none ABSTRACT: PURPOSE: Largest basal diameter of …

Measuring Choroidal Melanoma Basal Diameter: Using Ultrasound Vs. A New Wide–angle Fundus Camera לקריאה »

Visual Function-Specific Perimetry For Indirect Comparison Of Different Ganglion Cell Populations In Glaucoma

Sample PA, Bosworth CF, Blumenthal EZ, Girkin C, Weinreb RN. Invest Ophthalmol Vis Sci. 2000 Jun;41(7):1783-90. Department of Ophthalmology, University of California at San Diego, La Jolla 92093-0946, USA. ABSTRACT: PURPOSE: To compare short-wavelength automated perimetry, frequency-doubling technology perimetry, and motion-automated perimetry, each of which assesses different aspects of visual function, in eyes with glaucomatous …

Visual Function-Specific Perimetry For Indirect Comparison Of Different Ganglion Cell Populations In Glaucoma לקריאה »

Test-Retest Variability In Visual Field Testing Using Frequency Doubling Technology

Horani A, Frenkel S, Blumenthal EZ. Eur J Ophthalmol. 2007 Mar-Apr;17(2):203-7. Department of Ophthalmology, Hadassah University Hospital, and Hebrew University-Hadassah Medical School, Jerusalem 91120, Israel. ABSTRACT: PURPOSE: To quantify the magnitude of test-retest variability (TRV) for normal subjects in serial visual fields (VF) using the frequency doubling technology (FDT) instrument. METHODS: Twenty-one healthy adults, aged …

Test-Retest Variability In Visual Field Testing Using Frequency Doubling Technology לקריאה »

The Effect of Pupil Dilation on Scanning Laser Polarimetry with Variable Cornea Compensation

E.Z. Blumenthal, A. Horani and S. Frenkel Invest Ophthalmol Vis Sci 2004;45: E-Abstract 3311. © 2004 ARVO 3311 – B946 Dept of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel Commercial Relationships: E.Z. Blumenthal, Laser Diagnostic Technologies F; A. Horani, None; S. Frenkel, None. Grant Identification: none ABSTRACT: PURPOSE: Scanning laser polarimetry is routinely performed through a non–dilated pupil, since scanning through …

The Effect of Pupil Dilation on Scanning Laser Polarimetry with Variable Cornea Compensation לקריאה »

Inter-Device Reproducibility of the Scanning Laser Polarimeter with Variable Cornea Compensation

E.Z. Blumenthal and S. Frenkel Invest Ophthalmol Vis Sci 2003;44: E-Abstract 3390. © 2003 ARVO 3390 – B93 Dept of Ophthalmology, Hadassah University Hospital, Jerusalem, Israel Commercial Relationships: E.Z. Blumenthal, Laser Diagnostic Technologies F; S. Frenkel, None. ABSTRACT: PURPOSE: To evaluate the inter-device reproducibility of retinal nerve fiber layer (RNFL) thickness measurements obtained with the commercially available …

Inter-Device Reproducibility of the Scanning Laser Polarimeter with Variable Cornea Compensation לקריאה »

Short-Wavelength Automated Perimetry And Standard Perimetry In The Detection Of Progressive Optic Disc Cupping

Girkin CA, Emdadi A, Sample PA, Blumenthal EZ, Lee AC, Zangwill LM, Weinreb RN. Arch Ophthalmol. 2000 Sep;118(9):1231-6. Glaucoma Center, University of California-San Diego, 9500 Gilman Dr, La Jolla, CA 92093-0946, USA. ABSTRACT: OBJECTIVE: To compare progression in short-wavelength automated perimetry (SWAP) and white-on-white (standard) perimetry in eyes with progressive glaucomatous changes of the optic …

Short-Wavelength Automated Perimetry And Standard Perimetry In The Detection Of Progressive Optic Disc Cupping לקריאה »