גלאוקומה וקטרקט, פרופ' איתן בלומנטל

פרופ' בלומנטל

רשימת פרסומים מדעיים של פרופ’ בלומנטל

Retinal Nerve Fibre Layer Imaging Compared With Histological Measurements In A Human Eye

Blumenthal EZ, Parikh RS, Pe’er J, Naik M, Kaliner E, Cohen MJ, Prabakaran S, Kogan M, Thomas R. Eye (Lond). 2009 Jan;23(1):171-5. Epub 2007 Aug 24. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. eblumenthal@md.huji.ac.il ABSTRACT: PURPOSE: A feasibility study comparing retinal nerve fibre layer (RNFL) thickness values obtained with imaging devices against RNFL …

Retinal Nerve Fibre Layer Imaging Compared With Histological Measurements In A Human Eye לקריאה »

Retinal Nerve Fiber Layer Split Bundles Are True Anatomic Variants

Kaliner E, Cohen MJ, Miron H, Kogan M, Blumenthal EZ. Ophthalmology. 2007 Dec;114(12):2259-64. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. ABSTRACT: PURPOSE: The presence of retinal nerve fiber layer (RNFL) split bundles recently was described in normal eyes scanned using scanning laser polarimetry. In this study, the authors set out to ascertain whether …

Retinal Nerve Fiber Layer Split Bundles Are True Anatomic Variants לקריאה »

Reproducibility Of Nerve Fiber Layer Thickness Measurements By Use Of Optical Coherence Tomography

Blumenthal EZ, Williams JM, Weinreb RN, Girkin CA, Berry CC, Zangwill LM. Ophthalmology. 2000 Dec;107(12):2278-82. Glaucoma Center and Diagnostic Imaging Laboratory, Department of Ophthalmology, University of California, San Diego, USA. ABSTRACT: OBJECTIVE: To evaluate the reproducibility of optical coherence tomograph (OCT) retinal nerve fiber layer (RNFL) measurements in normal and glaucomatous eyes by means of …

Reproducibility Of Nerve Fiber Layer Thickness Measurements By Use Of Optical Coherence Tomography לקריאה »

Laser Photocoagulation Spot-Size Errors Stemming From The Refractive State Of The Surgeon’s Eye

Blumenthal EZ, Serpetopoulos CN. Ophthalmology. 2000 Feb;107(2):329-33. Department of Ophthalmology, Hadassah University Hospital, and Hebrew University-Hadassah Medical School, Jerusalem, Israel. ABSTRACT: PURPOSE: Meaningful errors in photocoagulation spot size may result from several factors. In this article we discuss one major factor, namely, fluctuations in the surgeon’s accommodative state, coupled with an inaccurate setting of the …

Laser Photocoagulation Spot-Size Errors Stemming From The Refractive State Of The Surgeon’s Eye לקריאה »

Estimating Intraocular Pressure Using A Glass Rod

Frenkel S, Katz S, Horani A, Kaiserman I, Asleh SA, Blumenthal EZ. Ann Ophthalmol (Skokie). 2006 Fall;38(3):195-9. Department of Ophthalmology, Hadassah-Hebrew University Medical Center, Jerusalem, Israel. eblumenthal@md.huji.ac.il ABSTRACT: Four masked examiners studied the usefulness of the glass-rod for estimating intraocular pressure (IOP) in a living, anesthetized rabbit eye manometrically set to 135 different random values. …

Estimating Intraocular Pressure Using A Glass Rod לקריאה »

Comparison Of Long-Term Variability For Standard And Short-Wavelength Automated Perimetry In Stable Glaucoma Patients

Blumenthal EZ, Sample PA, Zangwill L, Lee AC, Kono Y, Weinreb RN. Am J Ophthalmol. 2000 Mar;129(3):309-13. Glaucoma Center and Visual Function Laboratory, Department of Ophthalmology, University of California, San Diego, CA, USA. ABSTRACT: PURPOSE: To quantify and compare, on a point-by-point basis, the long-term variability of standard and short-wavelength automated perimetry in a group …

Comparison Of Long-Term Variability For Standard And Short-Wavelength Automated Perimetry In Stable Glaucoma Patients לקריאה »

Discriminating Between Normal And Glaucomatous Eyes Using The Heidelberg Retina Tomograph, Gdx Nerve Fiber Analyzer And The Optical Coherence Tomograph

Zangwill LM, Bowd C, Berry CC, Williams J, Blumenthal EZ, Sanchez-Galeana CA, Vasile C, Weinreb RN. Archives of Ophthalmology 2001;119(7):985-993 Glaucoma Center, Department of Ophthalmology, University of California-San Diego, La Jolla, CA 92093-0946, USA. ABSTRACT: OBJECTIVE: To compare the ability of 3 instruments, the Heidelberg Retina Tomograph (HRT), the GDx Nerve Fiber Analyzer (GDx), and …

Discriminating Between Normal And Glaucomatous Eyes Using The Heidelberg Retina Tomograph, Gdx Nerve Fiber Analyzer And The Optical Coherence Tomograph לקריאה »

Using Optical Imaging Summary Data To Detect Glaucoma

Sanchez-Galeana C, Bowd C, Blumenthal EZ, Gokhale PA, Zangwill LM, Weinreb RN. Ophthalmology. 2001 Oct;108(10):1812-8. Glaucoma Center, University of California San Diego, La Jolla, California 92093-0946, USA. ABSTRACT: PURPOSE: To evaluate the sensitivity and specificity for discriminating between early to moderate glaucomatous and normal eyes using summary data reports from the Heidelberg Retina Tomograph (HRT), …

Using Optical Imaging Summary Data To Detect Glaucoma לקריאה »

Detecting Early Glaucoma By Assessment Of Retinal Nerve Fiber Layer Thickness And Visual Function

Bowd C, Zangwill LM, Berry CC, Blumenthal EZ, Vasile C, Sanchez-Galeana C, Bosworth CF, Sample PA, Weinreb RN. Invest Ophthalmol Vis Sci. 2001 Aug;42(9):1993-2003. Glaucoma Center, Department of Ophthalmology, University of California San Diego, La Jolla 92093-0946, USA. ABSTRACT: PURPOSE: To compare the abilities of scanning laser polarimetry (SLP), optical coherence tomography (OCT), short-wavelength automated …

Detecting Early Glaucoma By Assessment Of Retinal Nerve Fiber Layer Thickness And Visual Function לקריאה »

Imaging Of The Optic Disc And Retinal Nerve Fiber Layer: The Effects Of Age, Optic Disc Area, Refractive Error, And Gender

Bowd C, Zangwill LM, Blumenthal EZ, Vasile C, Boehm AG, Gokhale PA, Mohammadi K, Amini P, Sankary TM, Weinreb RN. J Opt Soc Am A Opt Image Sci Vis. 2002 Jan;19(1):197-207. Glaucoma Center, Department of Ophthalmology, University of California, San Diego, La Jolla 92093-0946, USA. cbowd@eyecenter.ucsd.edu ABSTRACT: We cross-sectionally examined the relationship between age, optic …

Imaging Of The Optic Disc And Retinal Nerve Fiber Layer: The Effects Of Age, Optic Disc Area, Refractive Error, And Gender לקריאה »